Prima Lux

PRIMA LUX is an high-tech diode laser designed for the dental practice that wants to offer to its patients non-invasive, targeted and effective dental and aesthetic treatments,with a great prognostic predictability.

The intrinsic properties of the diode light radiation, the anti-inflammatory and decontamination actions, the bio-stimulating effect, the analgesic and hemostatic capacity - are fulfilled by a large number of pre-set dental programs and dermatological/aesthetic applications supplied with clinically validated operating protocols.

Equipped with specific handpieces for surgery, therapy and aesthetic treatments, PRIMA LUX stands out as an innovative, reliable and easy to use instrument offering highly efficient performances by putting all the clinical benefits of laser therapy at service of smile care and facial beauty.


Design

Compact shape, modern design and easy installation are the features that make PRIMA LUX perfectly fitting to any dentist office and easily transportable from a dental surgery to another.


Large display

A wide alphanumeric LCD on the main screen allows to distinctly read all the parameters visualized and permit to control the main settings at any moment of the clinical practice.


Handpieces

PRIMA LUXis equipped with ergonomic handpieces which allow firm gripping and easy handling. Optical fibers conveying laser radiations are housed in though sheathes and supported by a thin stem that enables the practitioner to move freely.


Upgradability

Thanks to a special internal microprocessor, PRIMA LUX turns out to be an easily updatable device: new functions and treatments can be added. The updating is easy and makes PRIMA LUX an unsurpassed instrument always up-to-date with the latest clinical applications.


Safety

Innovative elements make our PRIMA LUX one of the safest laser systems in the market sale also for hospital use. Some of them are, for instance, the protective glasses, the interlock system which automatically stops the laser radiation in case of access doors opening, the light signal to be placed outside the dental surgery during laser emission.

No Touch System

the doctor can set up all the parameters and interact with the device only using his feet, thus having his hands free of moving in the operating scope.


Clinical advantages

Instrument of choice in periodontics for its excellent antibacterial action in the treatment of infected pockets and of perimplantitis, PRIMA LUX is an equally irreplaceable aid in endodontics in the treatment of root canals, of dentinal hypersensitivity and in dentin vitrification.

In surgery, its special ability to vaporize muco-gingival flaps and its high coagulating power without tissue carbonization or necrotizing effects, make it an effective and decisive instrument in many applications including frenectomy, fibroids excision, herpes, mouth ulcers, fistulas, vascular lesions, abscesses, epulis treatments.

The anti-inflammatory and analgesic properties of the diode laser, in addition, involve a drastic reduction in the use of anaesthetic and are critical in the traumatologic-analgesic field, especially in the treatment of myofascial pain syndrome, infection of the ATM, carpal tunnel and paresthesia.

Under the dermatological-aesthetic point of view, finally, the painless effectiveness and non-invasiveness of photodynamic therapy of PRIMA LUX are expressed in a large number of applications such as psoriasis, senile freckles, xanthelasma, folliculitis, keratosis, photorejuvenation, acne scars in addition to tooth whitening, whose specific protocol allows to avoid the risk of dentin sensitization that occurs,however, with the use of other instruments such as bleaching lamps.


The treatments

All the set-up treatments provided by PRIMA LUX result from an accurate clinical validation and make reference to preeminent studies published on the most prestigious scientific journals. Among our personnel we can count on a skilled medical staff who thoroughly check that PRIMA LUX parameters are lined up with the above mentioned studies.

Prima Lux LightPrima Lux
Power supply100-240 V AC100-240 V AC
Power frequency50-60 Hz50-60 Hz
Input maximum power1,5 A AC1,5 A AC
Output power12 V DC ; 4,17 A12 V DC ; 4,17 A
Maximum current absorbed by the system2 A3 A
Maximum laser power on working point3 W5 W
Medical classII BII B
Insulation classI - type BF applied partI - type BF applied part
Laser classIVIV
Dimensions24x28x8 cm24x28x8 cm
Weight2kg approx.2kg approx.
MAIN PARAMETERS
Power0,1 W - 3,0 W0,1 W - 5,0 W
Laser emission modeSelectable: Continuous - 1000 HzSelectable: Continuous - 1000 Hz
Duty Cycle50%50%
Operating modeContinuous - Timed min 1s, max 99s – 30 min.Continuous - Timed min 1s, max 99s – 30 min.
Emission power stability± 20%± 20%
Wavelength808nm808nm
Laser source power10W10W

    SUPPLIED ACCESSORIES:

    • Surgical handpiece
    • 300 µm optical fiber
    • Couple of protective goggles
    • Fiber-cutter
    • Fiber-skinner
    • Fiber-bearing stem
    • Foot control pedal
    • Clinical protocols
    • User manual

    OPTIONAL ACCESSORIES:

    • 200µm optical fiber
    • 400µm optical fiber
    • Therapeutic handpiece
    • Handpiece for wide areas – aesthetic use